An approved On-Site Sewage Facility (OSSF) Plan is generally required before an OSSF can be constructed, altered, repaired, or expanded. The plan documents how the system will be designed and installed based on the property, site conditions, and wastewater needs.

 Project Exemptions

Certain exceptions are codified in TAC 30 Chapter 285, Subchapter A, Rule §285.3

Background

An OSSF Plan is a detailed collection of prepared documents that outlines the design, installation, operation, and maintenance of an OSSF. The plan serves as a roadmap for construction and managing wastewater generated on a specific property when a connection to a public sewer system is not available or feasible. To ensure the efficient treatment and disposal of wastewater, while minimizing environmental impact and public health risks, OSSF Plans takes into account various factors, such as:

  • Property size
  • Soil characteristics
  • Water table levels
  • Local regulations

Property that will use an OSSF for sewage disposal must be evaluated for overall site suitability, and evaluations and planning materials must be prepared by a professional engineer or professional sanitarian.

Note: If a system is proposed to use over 5,000 gallons of water per day or the total disposal on the tract is proposed for over 5,000 gallons per day, the system can no longer be permitted under OSSF rules and must be permitted through Texas Commission on Environmental Quality (TCEQ).

Information Included in an On-Site Sewage Facility Plan

To document the soil and site conditions, a complete site evaluation must be performed by either a licensed site evaluator or a professional engineer on every tract of land where an OSSF will be installed, and their report providing the site evaluation criteria must be submitted with the planning materials. This evaluation assesses soil permeability, depth to groundwater, topography, and other relevant factors to determine the suitability of the site for on-site sewage disposal.
Their report should include a:

  • Detailed soil profile
  • Profile test hole locations
  • Suitable disposal options
  • Any other relevant findings

Detailed requirements are codified in TAC 30 Chapter 285, Subchapter D, Rule §285.30 and other state and local codes.

Can’t find what you’re looking for?

If you can’t find information about a specific permit or need help, fill out the Contact & Feedback Form. We will get back to you shortly.

You can also request a pre-application meeting to discuss any questions about your project by submitting a Request a Pre-Development Meeting.

For other ways to reach us, visit our Contact page.

Development Services Contact Card

Contact & Feedback Form

Request a Pre-Development Meeting

Phone

(512) 854-4215

Permit Desk Hours

Monday - Thursday
9:00 AM - 2:00 PM

Street Address

700 Lavaca
Suite 540
Austin, TX 78701
(Map)

Mailing Address

P.O. Box 1748
Attn: Permits
Austin, TX 78701

Social Media

 

More Resources